Optical Smoke Detector
FC600/O
• Addressable conventional technology
• Individual detector identification with
optional address module
• Allows for connection of external
remote indicator
• Anti-tamper locking feature on
detector base
• Double dust trap and insect screen
• Function check by means of test
magnet or test gas
Description
The Optical Smoke Detector FC600/O is based on the
IR light scattering principle and offers superior wide-
spectrum detection of smoke aerosols generated by
the majority of fires. A symmetrical detection chamber
allows for optimal smoke sensitivity from all directions.
Any alarm will be transmitted to the fire detection pa-
nel in conventional technology. An individual detector
identification can be obtained with the optional Address
Module NG58-1.
An automatic drift compensation keeps the response
sensitivity of the detector constant for a long period.
The double dust trap effectively protects the detector
FC600/O against false alarms resulting from dust con-
tamination and ambient light. An insect screen prevents
insects from interfering with the detection chamber.
Several types of detector bases are available to faci-
litate quick and easy installation. To prevent unautho-
rized removal of the detector, all detector bases are
equipped with an anti-tamper locking feature.
The detector is equipped with an LED indicator which
is visible from all sides at any angle and thus facilitates
easy identification of the alarming detector. In addition,
a remote indicator can also be connected.
A detector function test can be conveniently conducted
by using either a test magnet or test gas.
Specifications
Operating voltage
Current consumption
Ambient temperature
Relative humidity
Dimensions ø × h (without base)
Colour
10 – 30VDC (supply through detector line voltage)
typ. 75µA (normal condition)
-30°C to +70°C
max. 95% (no condensation)
106 × 46 (mm)
white
Weight
80g
Approvals
LPCB 603a/01
0832-CPD-0125
Order number
Order name
241070
0832–CPD–0125
Optical Smoke Detector/Conv./FC600 FC600/O
Building Safety. Building Security.
A
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
FC600-O_DBL_LST_EN_0850.PDF • PAGE 1
OFFICE@LST.AT • WWW.LST.AT • ALL RIGHTS RESERVED
|
Kyocera Telescope KD135SX UPU User Manual
Land Pride Lawn Mower RB05 Series User Manual
Lanier Headphones 480 0066 User Manual
LG Electronics Flat Panel Television OLED55B6P User Manual
LG Electronics Portable DVD Player DP570MH User Manual
Lightolier Stereo System RD Cable User Manual
M 2GR45MF 2GR65MR 2GR85MF 3GR45MF 3GR65MF 3GR85MF 4GR45MF ML 136407 ML 136408 ML 136409 ML 136410 ML 136417 ML 136418 ML 136419 ML 136420 ML 136421 ML 136422 ML 136423 User Manual
Magnavox CRT Television 29MT4515 User Manual
Magnavox Stereo System US2 MANT050 User Manual
Maretron Switch SIM100 User Manual